32
QUADRO 4. Pontas inspecionadas e respectivas equações lineares para cálculo
de vazão.
Especificação da
ponta Pressão (BAR)
Intervalo de
pressão (BAR)
Pressão mínima
(BAR)
Pressão máxima
(BAR)
Vazão
mínima
(L/min)
Vazão
máxima
(L/min) Equação de ajuste
Vazão
calculada
(L/min)
AVI 110.03 3.657 2.1 a 6.3 3.2 4.2 1.2 1.39 0.1574x + 0.713 1.289
AVI 110.03 3.657 2.1 a 6.3 3.2 4.2 1.2 1.39 0.1574x + 0.713 1.289
JÁ-2 4.219 4.2 a 10.5 4.2 6.3 0.64 0.76 0.0569x + 0.4 0.640
JÁ-2 4.079 4.2 a 10.6 4.2 6.3 0.64 0.76 0.0569x + 0.4 0.632
XR 110.01 2.110 1.0 a 4.0 2 2.5 0.32 0.36 0.072x + 0.1753 0.327
AVI 110.025 3.516 2.1 a 6.3 3.2 4.2 1 1.16 0.1327x + 0.59 1.057
AVI 110.025 3.516 2.1 a 6.4 3.2 4.2 1 1.16 0.1327x + 0.59 1.057
AXI 110.02 2.110 1,1 a 2,8 2.1 2.8 0.7 0.8 0.1422x + 0.4 0.700
ADI 110.02 3.516 1.4 a 2.8 1.4 2.8 0.57 0.8 0.1422x + 0.4 0.900
XR 110.03 2.110 1.0 a 4.0 2 2.5 0.97 1.08 0.2103x + 0.5417 0.985
AVI 110.02 2.461 2.1 a 6.3 2.1 3.2 0.66 0.8 0.1043x + 0.47 0.727
TT 110.03 VP 1.406 1.0 a 6.0 1 1.5 0.68 0.84 0.1824x + 0.6129 0.869
JÁ-2 8.439 4.2 a 10.5 6.3 10.5 0.76 1 0.0569x + 0.4 0.880
JÁ-2 8.439 4.2 a 10.6 6.3 10.5 0.76 1 0.0569x + 0.4 0.880
AVI 110.025 5.274 2.1 a 6.3 5.3 6.3 1.3 1.42 0.1327x + 0.59 1.290
AVI 110.025 5.274 2.1 a 6.4 5.3 6.3 1.3 1.42 0.1327x + 0.59 1.290
XR 110.02 2.813 1.0 a 5.0 2.5 3 0.548 0.6 0.099x + 0.2921 0.571
AVI 110.02 1.406 1.0 a 4.0 1 1.5 0.46 0.56 0.14x + 0.36 0.557
AVI 110.03 2.813 2.1 a 6.3 2.1 3.2 0.66 0.8 0.1574x + 0.713 1.156
TXA 80.03 2.461 1.0 a 5.0 2.5 3 1.095 1.2 0.1981x + 0.5844 1.072
AVI 110.03 3.516 2.1 a 6.3 3.2 4.2 1.2 1.39 0.1574x + 0.713 1.266
AVI 110.02 3.868 2.1 a 6.3 3.2 4.2 0.8 0.91 0.1043x + 0.47 0.873
AVI 110.02 3.516 2.1 a 6.3 3.2 4.2 0.8 0.91 0.1043x + 0.47 0.837
JÁ-2 2.813 4.2 a 10.6 4.2 10.6 0.64 1 0.0569x + 0.4 0.560
JÁ-2 2.813 4.2 a 10.6 4.2 10.6 0.64 1 0.0569x + 0.4 0.560
JÁ-5 2.110 4.2 a 10.5 4.2 10.5 1.6 2.44 0.1209x + 1.165 1.420
JÁ-5 3.516 4.2 a 10.5 4.2 10.5 1.6 2.44 0.1209x + 1.165 1.590
AD 110-015 4.923 1.0 a 5.0 4.5 5 0.734 0.775 0.1046x + 0.2708 0.786
AXI 110.03 2.461 1.1 a 2.8 2.1 2.8 1 1.1 0.1422x + 0.7 1.050
API 110.03 2.110 1.4 a 2.8 2.1 2.8 1.06 1.2 0.1991x + 0.64 1.060
110.02 DBA 2.813 1.0 a 4.0 2.5 3 0.72 0.79 0.14x + 0.36 0.754
110.015 DG 3.516 1.0 a 4.0 3.5 4 0.64 0.68 0.1046x + 0.2708 0.639
JÁ-2 5.626 4.2 a 10.6 4.2 6.3 0.64 0.76 0.0569x + 0.4 0.720
AXI 110.02 2.461 1.1 a 2.8 2.1 2.8 0.7 0.8 0.1422x + 0.4 0.750
BD 110.02 2.813 1.0 a 4.0 2.5 3 0.72 0.79 0.14x + 0.36 0.754
AD 110-015 2.813 1.0 a 5.0 2.5 3 0.54 0.59 0.1046x + 0.2708 0.565
AVI 110.015 5.626 2.1 a 6.3 5.3 6.3 0.77 0.85 0.0787x + 0.354 0.797
AXI 110.02 2.813 1.1 a 2.8 2.8 2.8 0.8 0.8 0.1422x + 0.4 0.800
AD 110-03 2.532 1.0 a 4.0 2.5 3 1.18 1.08 0.2103x + 0.5417 1.074
110.02 BD 1.758 1.0 a 4.0 1.5 2 0.56 0.64 0.14x + 0.36 0.606
AXI 110.03 2.461 1.1 a 2.8 2.1 2.8 1 1.1 0.1422x + 0.7 1.050
AD-110-05-D 2.813 1.0 a 4.0 2.5 3 1.8 1.97 0.3531x + 0.8922 1.885
AXI 110.03 2.110 1.1 a 2.8 2.1 2.8 1 1.1 0.1422x + 0.7 1.000
XR 110.03 2.813 1.0 a 4.0 2.5 3 1.08 1.18 0.2103x + 0.5417 1.133
TJ 60 110 02 1.406 2.0 a 4.0 2 4 0.64 0.91 0.126x + 0.408 0.585
Posteriormente, os dados foram registrados em planilha do Programa
Excel para análise. Este estudo permitiu avaliar o estado das pontas em relação
ao desgaste e/ou entupimento, tendo como vazão padrão aquela recomendada